HRJNY絕緣靴(手套)耐壓試驗裝置 |
|
|
★HRJNY型絕緣靴(手套)耐壓試驗裝置說明書 |
|
|
|
|
|
一、產品簡介
HRJNY型絕緣靴(手套)耐壓試驗裝置是我公司根據絕緣靴(手套)的試驗規程,并遵從廣大用戶意見而設計生產的。該產品有效的解決了過去不規則的測試方式,從而簡化了測試手續,提高了測試速度。更可靠地鑒別絕緣靴(手套)的泄漏電流,絕緣老化,工頻耐壓等參數。保障了試驗工作者的安全,是理想的絕緣靴(手套)專用設備。
其主要特點:
1) 可同時測試5雙測試絕緣靴(手套),并可讀取每雙的泄漏電流;
2) 電極采用H62銅材加工,表面鍍涂CU/EpNi5bc工藝,使表面放電量小于10pC;
3) 水箱采用全不銹鋼,放水口為球閥;
整體結構分二層,可靈活拆卸,底部裝配萬向輪,可隨意移動。
4)試驗設備分:手動配置型的和全自動配置型的。
|
|
|
二、主要技術參數
1) 水槽:(長)1040×(寬)680×(深)390
2) 底座:(長)1010×(寬)650×(深)330
3) 耐壓:3kV/1min
4) 測試量:每次5雙
5) 質量:80kg
適用于各種規格絕緣靴(手套)和帶電作業工器具的耐壓測量試驗。
工作電源:220V±10%,380V±10%
試驗電壓:0~500kV
工作頻率:50Hz
|
|
|
|
|
|
HRJNY
type insulating boots (gloves) withstand test device |
|
|
Brief introduction
HRJNY type insulating boots (gloves) withstand test device
is according to the company insulation boots (gloves) test
procedures and follow the masses of users advice which is
to design and manufacture. This product effectively solved
the past irregular test ways, which can simplify the test
procedures, enhances testing speed. This product effectively
solved the past irregular test ways, which can simplify
the test procedures, enhances testing speed. Ensure the
test workers safety, is the ideal insulating boots (gloves)
special equipment.
Main features
a) But the same test five pairs of test insulating boots
(gloves), and can read each pair of leakage current,
b) Electrode using H62 copper processing, surface coating
besmear CU/EpNi5bc processes, so that the surface is less
than 10pC; put power
c) Tanks are made of full stainless steel, match-fixing
mouth for ball valve
d) Test equipment points: manual and automatic configuration
of allocation type.
|
|
|
Technical parameters
Sink: (long) 1040 x (wide) 680 x (depth) 1140
Base: (long) 1010 x (650 x width) (depth) 330
Pressurization: 3kV/1min
Test quantity: every time five pairs
Quality: 80kg
For a variety of boots (gloves) and the live working tools
and instruments measure the pressure test.
Power supply: 220V ± 10%,380V±10%
Test Voltage: 0 ~ 500kV